Product Details:
LCR (Inductance / Capacitance / Resistance) Meter Compact full featured meter provides inductance, capacitance and resistance (LCR) measurements. Quickly and accurately measure capacitance values up to 600µF in seven ranges, resistance to 20MΩ in six ranges and inductance to 20H in five ranges.
|
 |
|
3 1/2 digit 1999 count display Transistor HFE measurement Diode test Audible continuity test Low battery display Comes complete with standard 9V battery, test clips and owners manual Specifications Dimensions: 6.77" (H) x 3.27" (W) x 1.50" (D) Primary accuracy specifications listed below. For complete accuracy and specification information, see the attached manual under the SPECS tab above.
| Resistance | | Range | Resolution | Accuracy | | 200Ω | 0.1Ω | ± (0.8% +3) | | 2KΩ | 1Ω | ± (0.8% +1) | | 20KΩ | 10Ω | ± (0.8% +1) | | 200KΩ | 100Ω | ± (0.8% +1) | | 2MΩ | 1KΩ | ± (0.8% +1) | | Capacitance | Range | Resolution | Accuracy | | 2.000nF | 0.001nF | ± (1% +5) | | 20.00nF | 0.01nF | ± (1% +5) | | 200.0nF; | 0.1nF | ± (1% +5) | | 2.000µF | 0.001µF | ± (4% +5) | | 20.00µF | 0.01µF | ± (4% +5) | | 200.0µF | 0.1µF | ± (4% +5) | | 600µF | 0.001mF | Reference only | | Inductance | Range | Resolution | Accuracy | | 2mH | 0.001mH | ± (2% +8) | | 20.00mH | 0.01mH | ± (2% +8) | | 200mH | 0.1mH | ± (2% +8) | | 2H | 0.001H | ± (5% +5) | | 20H | 0.001H | ± (5% +15) |
|
|
|
| Tenma Part# : 72-8155 |
Package Dimensions: |
RoHS Compliant: No  |
Weight: 1.10 lbs. |
| Hazmat: No |
Height: 2.00 in. |
| Static Sensitive: No |
Length: 8.00 in. |
|
Width: 6.00 in. |
|
|
Mfr. Name:
TENMA
|
Mfr. Part Number:
72-8155 |
 |
|
|
|
|
|
|
|